Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Medical Biomechanics ; (6): E027-E032, 2022.
Article in Chinese | WPRIM | ID: wpr-920664

ABSTRACT

Objective To explore the spatial distribution of microstructural parameters and mechanical properties for trabecular bone in the femoral head with osteonecrosis. Methods Microstructural parameters and mechanical properties of trabecular bone in different regions were analyzed by combined use of imaging measurements and numerical simulation method, and the spatial distribution of biomechanical properties for trabecular bone along coronal, sagittal and vertical directions was investigated. Results Microstructural characteristics and mechanical properties of trabecular bone were Y-shaped distributed along coronal and sagittal directions, and mechanical properties of trabecular bone in Y-shaped region were higher than those in the other regions. Such distribution characteristics was consistent with the location of principle compressive group in the femoral head. Conclusions Necrotic lesions in Y-shaped region had a greater influence on stress distribution of the femoral head and might cause the deterioration of osteonecrosis. The spacial correlation between necrotic lesions and Y-shaped region should be fully considered during clinical diagnosis.

2.
Journal of Medical Biomechanics ; (6): E256-E261, 2019.
Article in Chinese | WPRIM | ID: wpr-802451

ABSTRACT

Objective To study the change patterns of bone microstructural parameters around the magnesium based- implants after implantation in rabbit femur at different implantation time points. Methods The threaded and non-threaded high-purity magnesium (HP Mg, 99.99 wt.%) screws, with a 2 mm diameter and a 7 mm length, were implanted into the femoral condyle of the rabbits. The control group was the drilled and healthy group. Micro-CT scanning and analysis were performed at 8th, 12th and 16th week after operation. The obtained microstructural parameters included bone mineral density (BMD), bone volume fraction (BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), trabecular separation (Tb.Sp). Results At 8th week, BMD and BV/TV in non-threaded magnesium screw group were significantly higher than those in healthy group, Tb.N was significantly higher than that in drilled and healthy group, and Tb.Sp was significantly lower than that in healthy group. At 12th week, BMD, BV/TV and Tb.N in threaded magnesium screw group were significantly higher than those in drilled and healthy group, Tb.Th was significantly higher than that in healthy group, and Tb.Sp was significantly lower than that in drilled and healthy group. At 16th week, BMD, BV/TV and Tb.N in non-threaded magnesium screw group were significantly higher than those in drilled and healthy group, and Tb.Sp was significantly lower than that in drilled and healthy group. Conclusions The magnesium based-implant promoted higher BMD, BV/TV, Tb.Th, Tb.N and lower Tb.Sp of surrounding implant, indicating that osseointegration and bone growth were in good condition. Magnesium based-implant could effectively promote the regeneration of bone. The results provide a theoretical basis for the orthopedic application of magnesium based-implants in clinic.

SELECTION OF CITATIONS
SEARCH DETAIL